Object for monitoring and exporting alarms that defined in Alarm Manager.
Alarm View - Animation group
Alarm View - Animation - Visible property
Alarm View - Animation - Location X property
Alarm View - Animation - Location Y property
Alarm View - Animation - Height property
Alarm View - Animation - Width property
Alarm View - Wizard property
Adding Alarm View to the Screen:

Alarm View object located in the menu which opens when right clicked on empty space at Screen Designer.
Alarm View object properties
Adding Alarm View to Screen
Adding Alarm View to Screen
Alarm View object properties
Alarm View - Animation group
Alarm View - Animation - Visible property
Alarm View - Animation - Location X property
Alarm View - Animation - Location Y property
Alarm View - Animation - Height property
Alarm View - Animation - Width property
Alarm View - Wizard property
Alarm View - Wizard
Alarm View object
Alarm View - Enable property
Alarm View configured in two section as ToolStrip and Datagrid.
ToolStrip Configuration:
ToolStrip Configuration has 4 property group as Enable, Visible, Alignment and ToolStrip Properties. Configuration menu show up when right click on ToolStrip.
Enable Group:

Determines that which user level can run Acknowledge ve Acknowledge All functions.
Alarm View - Wizard - Toolstrip - Enable properties
Switching between these three section made by Active, Historical and Old Historical buttons.
Alarm View contains two type alarm as Alarm and Warning.

These alarm and warnings are separated in 3 section as Active, Historical and Old Historical.

When new alarm occured, it appears at the top row in Active Alarms section in the Alarm View.

For warnings, row background is yellow.
For alarms, row background is red.
When alarm is gone, text in the row becomes strike out. If going alarm acknowledged, it will be removed from active alarm list and located at the top row in Historical Alarms section.

Maximum 1000 alarm/warning can be reside in Historical section. Older alarms saved to txt file that named as month and year(1_2009.txt) in the project folder. These alarm/warnings can be viewed with Old Historical button or files opened by Excel also.
Alarm View - Active Alarms
Alarm View - Historical Alarms
First 3 button in ToolStrip enabled for Historical Alarms section.
Alarm Button: Displays only alarms  in Historical section.
Alarm Button
Warning Button
Alarm-Warning Button
Warning Button: Displays only warnings in Historical section.
Alarm-Warning Button: Displays all alarms in historical section.
Next 2 button in ToolStrip enabled for Active Alarms section.
Acknowledge button: Acknowledges selected alarm.
Acknowledge Button
Acknowledge All Button
Acknowledge All button: Acknowledges all alarms.
Last 2 button is used for exporting alarms as a text or Excel file.
Export Text File Button
Export Excel Button
Export Text File Button: Exports alarms to text file.
Export Excel Butonu: Exports alarms to Excel.
Visible Gurubu:

Determines ToolStrip buttons visibility.
Alarm View - Wizard - Toolstrip - Visible properties
Alignment Gurubu:

Determines ToolStrip buttons alignment.
Alarm View - Wizard - Toolstrip - ToolStrip Properties
Alarm View - Wizard - Toolstrip - Back Color property
Alarm View - Wizard - Toolstrip - Button Size property
ToolStrip Properties Gurubu:

Contains a settings about ToolStrip Location, Appearance and Button Size.
Alarm View - Wizard - Toolstrip - Location Property
ToolStrip Location:

ToolStrip Location is specified from Top Combobox.
Back Color:

Specifies ToolStrip Background Color.
Button Size:

Buton sizes can be specified as Big or Small.
DataGrid Configuration:
DataGrid Configuration has 2 property group as Visible and Date Time Format. Configuration menu show up when right click on DataGrid.
Alarm View - Wizard - Datagrid properties
Visible:

Determines columns visibility.
Alarm View - Wizard - Datagrid - Visible group
Date Time Format:

Determines Date Time format for Start Date Time and End Date Time columns.
Properties:

Alarm View object has a 3 property group as Animation, Enable and Wizard.
Animation Group:

Objects can be moved on horizontal and vertical axis and their size and visibilities can be changed.
Visible:

Used for determining object visibility. If tag's value 0 or negative which selected from tag list, object becomes hidden, if value bigger than 0 object becomes visible.
Location X:

Object's horizontal location can be changed by the tag which connected to object's Location X property.
Location Y:

Object's vertical location can be changed by the tag which connected to object's Location Y property.
Height:

Determines object's height. Tag's value which selected from tag list, determines object's height.
Width:

Determines objects width. Tag's value which selected from tag list, determines object's width.
Enable:

When tag's value bigger than 0, which selected from tag list, object becomes active. On other cases object is disabled.

This property can be used when object access is wanted to be controlled. Additionally, accessing to object can be controlled according to User Level with PasswordLevelX tags.









Wizard:

Alarm View configuration interface.
Alarm View - Enable property
Alarm View - Wizard
Alarm View - Wizard - Toolstrip properties
Alarm View - Wizard - Toolstrip - Enable properties
Alarm View - Wizard - Toolstrip - Visible properties
Alarm View - Wizard - Toolstrip - Alignment properties
Alarm View - Wizard - Toolstrip - ToolStrip Properties
Alarm View - Wizard - Toolstrip - Location Property
Alarm View - Wizard - Toolstrip - Back Color property
Alarm View - Wizard - Toolstrip - Button Size property
Alarm View - Wizard - Datagrid properties
Alarm View - Wizard - Datagrid - Visible group
Alarm View - Wizard - Datagrid - Date Time Format group
Alarm View - Wizard - Toolstrip properties
Historical Butonu
Active Butonu
Old Historical Butonu

                                                                                                                                                                       Alarm View
Active Butonu
Historical Butonu
Old Historical Butonu
Alarm Button
Warning Button
Alarm-Warning Button
Acknowledge Button
Acknowledge All Button
Export Text File Button
Export Excel Button
Alarm View - Locating Toolstrip at Left
Alarm View - Locating Toolstrip at Left
Using small buttons
Toolstrip - Using small buttons
Alarm View object
Alarm View - Active Alarms
Alarm View - Historical Alarms
Alarm View - Wizard - Toolstrip - Alignment properties
Alarm View - Wizard - Datagrid - Date Time Format group

                                                                                                                                                                               English                Turkish
Scada System        Scada Software        Free Scada            What is Scada
SCADA SOFTWARE